2 parameter setting – Lenze E94AYFLF Digital frequency module User Manual
Page 22

Digital frequency extension module | Parameter setting & configuration
Digital frequency output
Parameter setting
22
L
EDS94AYFLF EN 3.2 - 10/2010
3.2
Parameter setting
Short overview of the parameters for the digital frequency output:
Note!
Depending on the module receptacle the digital frequency extension module is
plugged in, different code ranges are assigned to the parameters!
• Module receptacle MXI1: Parameters are in the C130xx range
• Module receptacle MXI2: Parameters are in the C140xx range
Parameter
Info
Lenze setting
Value Unit
Signal source DFOUT
Application
No. of increments DFOUT
2048
Zero pulse offset DFOUT
0 Increments
Frequency limitation DFOUT
500 kHz
TP delay time DFOUT
0 μs
Speed at DFOUT
- Incr./ms
Frequency at DFOUT
- Hz
Position at DFOUT
- Increments
Resp. to frequency limit. DFOUT
Warning
Digital frequency extension module in module receptacle MXI1
Digital frequency extension module in module receptacle MXI2
Greyed out = display parameter