C13042 | resp. to vcc error dfin, C13050 | signal source dfout, C13051 | no. of increments dfout – Lenze E94AYFLF Digital frequency module User Manual
Page 36: C13052 | zero pulse offset dfout, C13042, C13050, C13051, C13052, Gital frequency output is selected in, The set number of increments

Digital frequency extension module | Parameter setting & configuration
Parameter reference
Parameter list | C13042
36
L
EDS94AYFLF EN 3.2 - 10/2010
C13042
C13050
C13051
C13052
Parameter | Name:
C13042 | Resp. to Vcc error DFIN
Data type: UNSIGNED_8
Index: 11533
d
= 2D0D
h
Digital frequency extension module in module receptacle MXI1:
Response when monitoring for encoder voltage supply at digital frequency input X9 is triggered
• Monitoring is triggered if the encoder voltage controlled by the digital frequency input reaches the voltage limit.
Selection list
(Lenze setting in bold)
1 Fault
2 Trouble
3 Quick stop by trouble
5 Warning
4 Warning locked
6 Information
0 No response
;
Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C13050 | Signal source DFOUT
Data type: UNSIGNED_8
Index: 11525
d
= 2D05
h
Digital frequency extension module in module receptacle MXI1:
Selection of the signal source for digital frequency output X10
Selection list
(Lenze setting in bold)
1 None
2 Digital frequency input DFIN
3 Motor feedback system
4 Load feedback system
5 Resolver
6 Encoder
7 Application [Incr./ms]
;
Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C13051 | No. of increments DFOUT
Data type: UNSIGNED_32
Index: 11524
d
= 2D04
h
Digital frequency extension module in module receptacle MXI1:
Number of increments for digital frequency output X10
• Definition of the number of pulses for one "mechanical" revolution.
Setting range
(min. value | unit | max. value)
Lenze setting
1
16384 2048
;
Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C13052 | Zero pulse offset DFOUT
Data type: UNSIGNED_16
Index: 11523
d
= 2D03
h
Digital frequency extension module in module receptacle MXI1:
Zero pulse offset for digital frequency output X10
• Offset for displacing the zero pulse to be output.
Setting range
(min. value | unit | max. value)
Lenze setting
0
Incr.
65535 0 increments
;
Read access ; Write access ; CINH PLC-STOP No transfer