Page 18

Function library "LenzeIo1000Drv"
Function blocks
L_io1000ParAoDc - Parameterise analog outputs
18
L
DMS 1.0 EN - 07/2011 - TD05
Outputs
Identifier/data type
Value/meaning
bDone
BOOL
TRUE Parameter setting completed successfully
dnState
DINT
Status of parameter setting
• When the function has been executed successfully, the value "0" is output.
1 Parameter setting started
0 Parameter setting completed successfully
-1003 byNodeAdr input is not in valid range
-1004 Wrong value at byAnalogModuleNo input
-1005 Wrong value at byNoOfChannels input
-2000 Error while executing the internal block for writing CAN indices
-2002 Wrong value at the dwHandle input
-2003 Wrong value at the byNodeAdr input
-2006 Writing of a wrong CAN index
-2007 Timeout while writing a CAN index of the I/O system
-2100 Error while writing a parameter of the I/O system
-2101 Output buffer is full