Function library "LenzeIo1000Drv"

Function blocks

L_io1000ParComGuarding - Parameterising monitoring functions

52

L

DMS 1.0 EN - 07/2011 - TD05

4.12

L_io1000ParComGuarding - Parameterising monitoring functions

This FB serves to parameterise the monitoring functions provided by the I/O system.

 This includes:

– NodeGuarding, heartbeat and Lenze-specific monitoring functions.
– Setting of the switching performance of the output channels in the event of an error

via the byErrorBehavior input.

 A FALSE/TRUE edge at the bExecute input starts the parameter setting.
 The dnState output shows the transmission status.

Call possible in:

;

Cyclic task

…

Interrupt task

;

Time-controlled task (INTERVAL)

…

Event-controlled task (EVENT)

L_io1000ParComGuarding

⎯ bExecute

bDone ⎯

⎯ dwHandle

dnState ⎯

⎯ byNodeAdr

DataTo_IOData15 ⎯

⎯ tGuardTime

DataTo_IOData610 ⎯

⎯ byLifeTimeFactor
⎯ tHeartbeatConsumerTime
⎯ byHeartbeatConsumerAdr
⎯ tHeartbeatProducerTime
⎯ byErrorBehavior
⎯ tTimeOutPDO1_DataToIO
⎯ tTimeOutPDO2_DataToIO
⎯ tTimeOutPDO3_DataToIO
⎯ tTimeOutPDO4_DataToIO
⎯ tTimeOutPDO5_DataToIO
⎯ tTimeOutPDO6_DataToIO
⎯ tTimeOutPDO7_DataToIO
⎯ tTimeOutPDO8_DataToIO
⎯ tTimeOutPDO9_DataToIO
⎯ tTimeOutPDO10_DataToIO
⎯ tTimeOutPDO1_DataFromIO
⎯ tTimeOutPDO2_DataFromIO
⎯ tTimeOutPDO3_DataFromIO
⎯ tTimeOutPDO4_DataFromIO
⎯ tTimeOutPDO5_DataFromIO
⎯ tTimeOutPDO6_DataFromIO
⎯ tTimeOutPDO7_DataFromIO
⎯ tTimeOutPDO8_DataFromIO
⎯ tTimeOutPDO9_DataFromIO
⎯ tTimeOutPDO10_DataFromIO