Loadstar Sensors DQ-1000A Frequency to Analog Interface User Manual

Dq-1000a frequency to analog interface user guide, Overview, Loadstar sensors, inc

Advertising
background image

GND

V

EXC

+

DC Power Input

Output Signals

V

EXC

-

5VDC

out

-

5VDC

out

+

20 mV-

20 mV+

SENSOR

DQ-1000A Frequency to

Analog Interface User Guide

Dimensions and Mounting Diagram

Instructions for Use

©

Overview

The Loadstar Sensors
DQ-1000 Single Channel
Frequency Interface provides
a simple and convenient
way for users to convert the
frequency output of an iLoad
Mini sensor to either a USB
digital output (DQ-1000U) or
analog outputs (DQ-1000A)
of 0—5 V DC and 0—20 mV.
When ordered together with
an iLoad Mini sensor, the
DQ-1000A can be calibrated
to the sensor to enable direct
0.5 V to 4.5V or compatibility
with legacy displays that ac-
cept 2 mV/V input.

This specification sheet is solely for the information and exclusive use of the original addressee and is not to be divulged in whole or in part by
any firm or individual without the express permission of Loadstar Sensors, Inc. The products described herein are not released for sale and may
not perform as specified in all respects.

Loadstar Sensors, Inc.

48089 Fremont Blvd.
Fremont, CA 94538
Phone: 510.623.9600
Fax: 510.623.9602

Loadstar Sensors’ Model DQ-1000 Single Channel Frequency-to-Analog
Interface takes the frequency output from an iLoad Mini sensor and converts
it to two different analog outputs: a 20 mV/V ratiometric output and a 0—5 V
DC analog output.

Notes

Note that the 5V DC Signal, the 20 mV- and the EXC- are all connected to the common ground.

1.

If you are using the ratiometric 20 mV/V output, the recommended excitation voltage (EXC+) is

2.

+10V. The minimum voltage is +5V.
The actual range of voltage for the 0—5V DC Signal output is from approximately 0.5V (at no load)

3.

to 4.5V at full load. The relationship between the load and voltage is on a calibration chart provided
with the sensor and DQ-1000A.

3.80

1.00

.12

.89

.12

3.24

1.40

4.20

4X R.20

4X

.19 THRU

3.80

1.00

.12

.89

.12

3.24

1.40

4.20

4X R.20

4X

.19 THRU

The picture (left) shows the ports of
the Frequency-to-Analog Interface.

URL: www.loadstarsensors.com • Email: [email protected]

Copyright Loadstar Sensors, Inc. 2013.

033-00983/-3

Advertising