- 16 -

Operation

1. Turn the power switch to the “ON” setting, the LCD display will show set current volume and the

cooling fan will beginning to revolve.

2. Adjust the Voltage/ Arc Force Knob and the Wire Speed / Stick Amps according to your needs.

3. Generally, welding current is adequate to welding electrode according with as following:

Specification

φ2.5

φ3.2

φ4.0

φ5.0

Current

70-100A

110-140A

170-220A

230-280A

4. The Arc Force knob is used to adjust welding function, specially in low current arrange, that is

cooperated with knob of welding current adjustment, they may adjust current of arc striking and be

out of control of knob of welding current adjustment .So machine can grain powerful energy and push

current can achieve effect that may.

5. VRD equipment is installed in the machine. When the switch of back panel is put "ON" position, the

VRD indictor is lit and the no-load voltage changes to be less than 15V, which is safe for people; and

when the switch is put "OFF" position, the VRD indicator is off.