To collapse the tripod (after removing the telescope), rotate

the spreader bar 60° from its assembled position, so that one

spreader bar arm is located between each adjacent pair of

tripod legs. At the base of the tripod is a three-vane extension

strut system, with a circular hub at its center (Fig. A, 7). Grasp

the tripod head (Fig. A, 1) with one hand and, with the other

hand, pull directly “up” on the central hub of the extension strut

system. This operation will cause the tripod legs to move inward

to a collapsed position.

CAUTION: If the tripod does not seem to extend or collapse

easily, do not force the tripod legs in or out. By following

the instructions above, the tripod will function properly,

but if you are unclear on the proper procedure, forcing the

tripod into an incorrect position may damage the extension

strut system.

C

Remove the covers of the battery compartments located

on the fork arms (one on each fork arm) and carefully lift the

battery holders from their compartments, being mindful of the

connector wires. Insert four (user-supplied) C-cell batteries into

each battery holder, oriented as shown on the diagram on the

battery holder. Return the battery holders to their respective

compartments. Replace the covers when you are done.

D

Press the computer control panel power switch to OFF, if

necessary. Remove the AutoStar II handbox and the AutoStar II

coil cord from the packing materials. Plug one end into the HBX

port of the telescope’s computer control panel (Fig. G) and plug

the other end into the coil cord port on the AutoStar II handbox.

Figure E. Loosen the leg lock knobs, extend the lower portion of
the leg and tighten the knobs (turn to a fi rm fi t).

Lock knobs

7

Qucik Start

E

Remove the travel screw on the rear OTA Use the provided

hex key to remove the travel screw (the position of the travel

screw will vary by OTA model) (Fig. H). DO NOT OPERATE THE

FOCUS KNOB BEFORE REMOVING THE SCREW or you will

damage your telescope. Place the provided black plastic cap in

the hole left by the travel screw. Retain the travel screw for use in

future shipments.

F

Attach the 1.25" Diagonal Remove the dust cap from the

rear cell of the telescope. Thread the eyepiece holder into the

rear cell thread. Slide the diagonal prism into the eyepiece holder

and lock in place by turning the thumbscrew to a fi rm feel.

Place the Super Plössl 26mm eyepiece into the diagonal prism

and tighten the attachment thumbscrew to a fi rm feel only.

G

Attach the Microfocuser (Optional Accessory) Remove

Figure F. The battery compartments are located on inside of
each of the fork arms.

Battery
compartment

Figure G. The LX600 control panel).

On/Off switch

HBX port

Figure H. Remove the travel screw before operating the focuser.
Return the travel screw before shipping the telescope.

Travel screw

Eyepiece

Thumbscrews

Diagonal prism

Rear cell port