Maintenance, Maintenance 37 – MTS Series 247 Actuators User Manual

Page 37

Advertising
background image

Series 247 Actuators

Maintenance

37

Maintenance

The Series 247 Actuators is designed for extended periods of operation without
extensive maintenance requirements.

The following table lists the recommended interval for each of these procedures.

Maintenance Intervals

*

*

The interval is based on an 8 hour a day, 5 days a week operation schedule. Dusty or dirty environments
require more frequent maintenance.

What to Do

When to Do It

How to do it

Clean the actuator

Every 40 hours of continuous
operation or weekly.

Clean exposed areas of the actuator piston
rod with a clean, dry, lint free rag.

If the actuator is continually exposed to a
dirty operating environment, clean the
piston rod on a daily basis.

Inspect the actuator for
wear

Monthly.

Inspect the actuator piston rod and seals for
excessive wear and/or leakage.

Small scratches in the axial direction of the
piston rod or polishing of the rod surface is
considered normal operating wear.

Replace the actuator
seals

Yearly or sooner if the actuator
inspection show excessive
leakage.

Arrange service with MTS Systems
Corporation.

Advertising