Specifications, Specifications 10 – MTS Model 512-01 Hydraulic Power Unit User Manual

Page 10

Advertising
background image

Model 512.01 Hydraulic Power Unit

10

Introduction

Specifications

Model 512.01 Specifications

P

ARAMETER

S

PECIFICATION

Environmental

Operating temperature

Heat load

*

Noise rating

at 1 m

18–35°C (65–95°F)

480 kcal/hr (1900 BTU/hr)

70 db (A)

Pump

Flow capacity
at 6.9 MPa (1000 psi)

Motor rating

Operating voltage

Starter type

3.8 l/m (1.0 gpm) @ 60 Hz

0.56 kW (0.75 hp)

115 V (ac) @ 13.8 A, 1 phase

Line voltage

Hydraulic Fluid

Nominal temperature

Filtration (microns)

Reservoir capacity

Mobil DTE 25

®

or Shell Tellus 46

®

46°C (115°F)

3 µ absolute

40 L (10 gal)

Heat exchanger

Air cooled

Hydraulic connections

Pressure

Return

Drain

each requires a 37° JIC flare

-6

-6

-6

Weight

88.5 kg (195 lb)

*

Specification is for 60 Hz operation.

Free field value [75 db (A)

heavy traffic at 17m]. Your readings

may be up to 10 db (A) more.