Specifications, Specifications 10 – MTS Model 512-01 Hydraulic Power Unit User Manual
Page 10
Model 512.01 Hydraulic Power Unit
10
Introduction
Specifications
Model 512.01 Specifications
P
ARAMETER
S
PECIFICATION
Environmental
Operating temperature
Heat load
*
Noise rating
†
at 1 m
18–35°C (65–95°F)
480 kcal/hr (1900 BTU/hr)
70 db (A)
Pump
Flow capacity
at 6.9 MPa (1000 psi)
Motor rating
Operating voltage
Starter type
3.8 l/m (1.0 gpm) @ 60 Hz
0.56 kW (0.75 hp)
115 V (ac) @ 13.8 A, 1 phase
Line voltage
Hydraulic Fluid
Nominal temperature
Filtration (microns)
Reservoir capacity
Mobil DTE 25
®
or Shell Tellus 46
®
46°C (115°F)
3 µ absolute
40 L (10 gal)
Heat exchanger
Air cooled
Hydraulic connections
Pressure
Return
Drain
each requires a 37° JIC flare
-6
-6
-6
Weight
88.5 kg (195 lb)
*
Specification is for 60 Hz operation.
†
Free field value [75 db (A)
≈
heavy traffic at 17m]. Your readings