MTS Model 512-01 Hydraulic Power Unit User Manual

Page 15

Advertising
background image

Model 512.01 Hydraulic Power Unit

Installation

15

4.

Test the HPU.

A.

Remove the 1/2” NPT pipe plug and install the breather in the
reservoir cover.

B.

Make sure all the pressure, return, and drain port caps are in
place.

C.

Press the

Start

button (be sure the

Stop

button is released).

D.

Check that the output pressure is less than 6.9 MPa (1000 psi).

E.

Press the

Stop

button.

5.

Connect the hydraulic lines.

See

“Component Identification”

on page 13 to determine the locations

of the hydraulic connections to the HPU. See the following table to
identify the size of each hydraulic connection.

NOTE

Some maintenance procedures require you to set the HPU for a no-
flow condition (where no fluid is flowing to other hydraulic
equipment). You may want to consider plumbing in a bypass circuit
in the system hydraulic lines.

Hydraulic Connectors

C

ONNECTOR

S

IZE

Pressure, 37º flare

-6

Return, 37º flare

-6

Drain, 37º flare

-6