252 servovalve performance characteristics, 252 servovalve performance characteristics 22, Flow versus frequency performance curves – MTS Series 252 Servovalves User Manual

Page 22: Series 252 servovalve product information

Advertising
background image

Series 252 Servovalve Product Information

22

252 Servovalve Performance Characteristics

Introduction

252 Servovalve Performance Characteristics

The flow versus frequency performance curves are shown in the following
figures. They indicate the typical performance capabilities of the servovalves at
various frequencies. The curves are derived by driving the servovalve at the
indicated frequency with a sine wave control signal and ± full current to the coil.

Note

Performance in the following graphs are with 21 MPa (3000 psi) pressure
supplied and 7 MPa (1000 psi) pressure drop across the servovalve.

Flow versus Frequency Performance Curves

1

100

10

378

0.1

37

3.7

0.37

1000

100

10

1

Frequency in Hz

Flow in Liters Per Minute

Flow in Gallons Per Minute

252.33

252.32

252.31

1

100

10

378

0.1

37

3.7

0.37

1000

100

10

1

Frequency in Hz

Flow in Liters Per Minute

Flow in Gallons Per Minute

252.43

252.42

252.41

378

37

3.7

0.37

Frequency in Hz

Flow in Liters Per Minute

Flow in Gallons Per Minute

1

100

10

0.1

1000

100

10

1

252.21

252.25

252.24

252.22

252.23

252.2x

252.3x

252.4x

Advertising