4 rear panel, Digital effects processor, Installation – Behringer Europower PMP518M User Manual

Page 7: 1 mains connection, 2 audio connections, Digital effects processor 4. installation, 1 mains connection 4.2 audio connections, Digital effects processor 3, Installation 4

Advertising
background image

7

EUROPOWER PMP518M User Manual

behringer.com

Rear panel

2.4

The mains connection is on a standard IEC receptacle. An appropriate power

[23]

cord is supplied with the unit.
FUSE HOLDER

[24]

. Before connecting the unit to the mains, ensure that

the voltage setting matches your local voltage. Blown fuses should only

be replaced by fuses of the same type and rating. Please also read the

information given in chapter 6 “Specifications”.
The three

[25]

PARALLEL SPEAKER OUtPUts provide the mono main signal on

a Neutrik Speakon-compatible connector (pins 1+/1- and 2+/2-) and on two

1/4" TS connectors.
The impedance of the loudspeaker connected must not fall below 4 Ω.

Information on how to properly connect your speaker with regard to

polarity can be found on the rear of the mixer (PINOUTs).
This is the cooling fan of the unit.

[26]

SERIAL NUMBER

[27]

.

Digital Effects Processor

3.

100 FIRST-CLASS EFFECTS
The PMP518M features a built-in digital effects processor. This effects processor

offers a large number of standard effects such as Hall, Chorus, Flanger, Delay and

various combination effects. Using the FX control, you can feed signals into the

effects processor. The integrated effects module has the advantage of requiring

no wiring. This way, the danger of creating ground loops or uneven signal levels

is eliminated at the outset, completely simplifying the handling.
Presets 00 - 09:

Hall

Presets 10 - 19:

Room

Presets 20 - 29:

Plate

Presets 30 - 39:

Gated/Reverse

Presets 40 - 49:

Early Reflections

Presets 50 - 59:

Delay

Presets 60 - 69:

Chorus

Presets 70 - 79:

Phase/Pitch

Presets 80 - 89:

Multi 1

Presets 90 - 99:

Multi 2

Installation

4.

Mains connection

4.1

Blown fuses must be replaced by fuses of the same type and rating.
The mains connection is made using the enclosed power cord and a standard IEC

receptacle. It meets all of the international safety certification requirements.

Please make sure that all units have a proper ground connection.

For your own safety, never remove or disable the ground conductor
from the unit or of the AC power cord.

Audio connections

4.2

The inputs and outputs of the BEHRINGER EUROPOWER are unbalanced

1/4" TS connectors — except for the balanced mono line inputs and the

balanced XLR inputs. Of course, all inputs and outputs work with both balanced

and unbalanced connectors. The Tape Ins and Outs are on RCA connectors.

Please ensure that only qualified personnel install and operate the

power mixer. During installation and operation, the user must have
sufficient electrical contact to earth. Electrostatic charges might affect
the operation of the unit.

Strain relief clamp

Sleeve

Tip

Sleeve
(ground/shield)

Unbalanced ¼" TS connector

Tip
(signal)

Fig. 4.1: 1/4" TS connector

{25]

[24]

[23]

[27]

[26]

Fig. 2.2: Rear panel control elements and connectors

Advertising