Maintenance, Machine inspection, Tightening torque – Multiquip MVH508DZ User Manual

Page 26: Engine air cleaner

Advertising
background image

PAGE 26 — MVH508DZ PLATE COMPACTOR • OPERATION AND PARTS MANUAL — REV. #0 (04/04/14)

MAINTENANCE

MACHINE INSPECTION

Perform machine inspection as listed in Table 6.

Table 6. Machine Inspection

Interval

Check

Solution

Daily Before Starting

Machine

Clean if necessary.

Fuel Tank For Leaks

Repair fuel leaks.

Fuel System for Leaks

Repair fuel leaks.

Engine Oil

Add oil if necessary.

Vibrator Oil

Add oil if necessary.

Air Cleaner Element

Clean/Replace

Guard Frame

Inspect/deformations

Shock Absorber

Replace if damaged.

Hydraulic pump

Check/Repair Leaks

Hydraulic Pipe System

Check/Repair leaks,

Inspect for wear

Direction Control Lever

Check bolts/nuts,

Inspect for wear

Duct Hose

Check for crack/

damage

Every 20 Hours

Engine Oil/Oil Filter

Replace only after

first 20 hrs.

Every 100 Hours

Engine Oil

Change

Engine Oil Filter

Wash

Vibrator Oil

Check oil level.

Check for leaks/dirt.

Hydraulic Oil

Check oil level.

Check for leaks.

Battery Terminal

Clean

Every 200 hours

V-Belt

Inspect, replace if

damaged or worn.

Clutch

Inspect, replace if not

working properly.

Engine Bolts

Replace bolts

if deformed or

elongated.

Every 300 hours

Vibrator Oil

Change

Fuel Filter

Change

Hydraulic Oil

Change

Engine Oil Filter

Change

Every 2 years

Fuel Lines

Replace

TIGHTENING TORQUE

Reference Table 7 below (Tightening Torque ), for retight-

ening of nuts and bolts.

ENGINE AIR CLEANER

This engine is equipped with a replaceable, high-density

paper air cleaner element. See (Figure 21) for air cleaner

components.
1. Remove the air cleaner cover and foam filter element.
2. Tap the paper filter element several times on a hard

surface to remove dirt, or blow compressed air not

exceeding 30 psi (207 kPa, 2.1 kgf/cm

2

) through the

filter element from the inside out.

NEVER brush off

dirt. Brushing will force dirt into the fibers. Replace the

paper filter element if it is excessively dirty.

Table 7. Tightening Torque (in. kg/cm Diameter)

Material

6mm

8mm

10mm

12mm

14mm

16mm

18mm

20mm

4T

70

150

300

500

750

1,100

1,400

2,000

6-8T

100

250

500

800

1,300

2,000

2,700

3,800

11T

150

400

800

1,200

2,000

2,900

4,200

5,600

*

100 (6mm) 300 ~ 350 (8mm) 650 ~ 700 (10mm)

**

In case counter-part is of aluminum

Bolt threads used with this machine are all right handed

Material and quality of material is marked on each bolt, and screw.

DANGER

DO NOT use gasoline or low flash point

solvents for cleaning the air cleaner. The

possibility exists of fire or explosion which

can cause damage to the equipment and

severe bodily harm or even

DEATH!

CAUTION

Wear protective equipment such as

approved safety glasses or face shields

and dust masks or respirators when

cleaning air filters with compressed air.

Advertising