Maintenance – Multiquip MVH508DZ User Manual

Page 30

Advertising
background image

PAGE 30 — MVH508DZ PLATE COMPACTOR • OPERATION AND PARTS MANUAL — REV. #0 (04/04/14)

MAINTENANCE

BATTERY

The standard battery is a maintenance-free battery. It is

not necessary to supply battery fluid. In case of a sudden

voltage drop, the battery cannot be charged quickly, so it

has to be replaced with a new one.

Checking Battery Capacity

1. Check the battery checker on the hour tachometer

(Figure 32).

Figure 32. Battery Check

2. When the battery charge gets low, the battery checker

lights red.

Changing the Battery

1. Unlatch the two stoppers at the top portion of the rear

cover to open the rear cover (Figure 33).

Figure 33. Opening Rear Cover

.

NOTICE

Battery is not included with this machine

DIESEL ENGINE TACH &HOUR METER

Battery checker

HOUR TACHOMETER

NOTICE

If an old battery is used, even when the battery checker

is not lighted (indicating low charge), the cell starter

might not operate because of low charging level. If that

happens, change the battery with the new one.

Rear cover

Stopper

2. Loosen the two bolts on each side of the bar connecting

the battery to the side rails (Figure 34).

Figure 34. Raising the Battery

3. Slide the bar up the notches for easy access to the

battery and tighten the bolts.

4. Take off the nuts and remove the battery holder

(Figure 35).

5. After tilting the battery backward, disconnect the

battery terminal. Always disconnect the black terminal

on the negative side first.

6. Pull up the handle on the top of the battery to remove

the battery from the machine.(Figure 35). Make sure

that the battery terminals do not touch the frame.

SLIDE BAR UPWARD

TO ACCESS

BATTERY

LOOSEN

BOLT

(4 PLACES)

BATTERY

Advertising