page 20 — st4/st6 series submersible pumps • operation anD parts manual — rev. #1 (11/12/13)

oPeraTion

reset button

1. When the electronic overload module detects an

overload condition, the pump will shut down. Check the

pump and correct the cause of ther overload.

2. Let the pump cool down, then press the

RESET button

(see Figure 14) on the front of the control box to restore

power.

Figure 14. RESET Button

shut-Down

1. Place the 3-position operation switch on the control

box to the

oFF position (Figure 15).

Figure 15. Manual-Off-Auto SW.

(OFF Position)

2. Verify that the control box power

on light is oFF.

3. Turn the circuit breaker or quick disconnect switch to

the

oFF position.

4. Using a suitable lifting device, lift the pump up from

its current position and place on a secure flat surface.

5. Remove the discharge hose from the discharge port

on the pump.

6. Remove all power cables and float switches from

the control box. Place cables and float switches in a

suitable container where they will not get damaged.

7. If the pump was used to pump mud, grit or silt, flush

vigorously with clean water.

8. Wipe off any mud or debris that might have attached

itself to the pump.

9. Store pump in a clean dry place away from dirt and

debris.

Control box operation (manual mode)

1. From the voltage source, set the circuit breaker or quick

disconnect switch to the

on position.

2. For manual operation of the pump, place the 3-position

operation switch (Figure 11) on the control box in the

manual position.

Figure 11. Manual-Off-Auto SW.

(Manual Position)

3. Verify that the

on indicator (Figure 12) on the control

box is

LIT. This means that power is being supplied to

the control box.

Figure 12. Control Box Power ON Indicator

4. In the manual mode the pump will run continuously. Pay

close attention when running the pump in this mode.

Damage to the pump may occur if pump is not fully

immersed in water.

Control box operation (auto mode)

1. To operate the pump automatically (float switches),

place the 3-position operation switch in the

auto

position (Figure 13).

Figure 13. Manual-Off-Auto SW.

(Auto Position)

2. In the

auto mode the pump will run as long as there

is a sufficient amount of water. This amount of water

is determined by the setting of the float switches. The

stop float switch contacts will open when the water

level is low and power will be removed from the pump's

electric motor.
Once the water level has risen back to the appropriate

level the

start float switch contacts will close and power

will be restored to the pump's motor.