Maintenance, Drive motor maintenance, Bronze wear bushing replacement – Multiquip Cv1A User Manual

Page 20: Flexshaft lubrication (100 hours)

Advertising
background image

page 20 — CV seRIes VIbRatoR motoR • opeRatIon and paRts manual — ReV. #0 (04/30/13)

Maintenance

dRIVe motoR maIntenanCe

1. Visually inspect the motor daily before use for defective

or missing parts, and have repairs made before use.

2. Inspect brushes frequently and replace when they

become worn to a length of 3/8". See Length A in

Figure 8.

Figure 8. Brush Length

3. Keep air inlet and air exit louvers clean and free of

concrete and debris. Failure to do so will result in rapid

motor overheating and parts failure.

4. Clean air filter as needed. If unit is used in high dust

areas, filter will have to be cleaned more often.

5. Use a screw driver to tighten brush caps.

do not

oVeRtIgHten. The brush cap must be tight enough

that the brush holder does not move.'

bRonze WeaR busHIng ReplaCement

Refer to Figure 9 for location of parts.

Figure 9. Bronze Wear Bushing

A

SLOTTED SPRING PIN

QUICK-DISCONNECT KNOB

SPRING HOUSING

OUTPUT ENDBELL SHAFT

LOCK PIN

SHAFT COUPLING

BRONZE WEAR BUSHING

COMPRESSION SPRING

1. If installed, remove head assembly and shaft coupling.
2. Remove slotted spring using hammer and punch of

appropriate size.

3. Once the pin is removed, the quick-disconnect knob,

compression spring, and lock pin can easily be

removed.

FleXsHaFt lubRICatIon (100 HouRs)

4. Using a bench vice and wrench, remove coupler from

flexshaft as shown in Figure 10. Please note threads

are

right-handed on this side of the flexshaft (drive

motor end).

5. Heat should be applied to the threads to break down

the anaerobic sealant. Applying heat will help prevent

possible damage to threads.

6. Next, using a wrench and bench vise if necessary,

remove flexible shaft from vibrator head as shown in

Figure 10. Please note threads are

left-handed on this

side of the flexshaft (vibrator end).

7. Pull the wire core out from casing. Using a clean soft

cloth, wipe the grease off as the wire core is pulled

from the casing. Wipe clean.

Figure 10. Removing Wire Core

8. Inspect the core for broken wires, permanent set, or

other damage such as an area that indicates high wear

or having overheated. If any of these conditions exists,

replace wire core.

VIBRATOR

HEAD

LEFT-HAND

THREAD

RIGHT-HAND

THREAD

BENCH

VISE

APPLY

HEAT

FLEXSHAFT

APPLY

HEAT

COUPLER

Advertising