Wiring Instructions
1 - Cable preparation
Length of wire stripping
• Contact # 16 L = 7 mm
• Contact # 12 L = 9 mm
• Contact # 8 L = 9 mm
2 - Contact insertion
Take the crimped wire, insert the contact into the cavity
and then push it until the mechanical stop.
Pull slightly on the wire to be sure that the contact
is in the right position.
The choice of the crimping tools we recommand on page 20, has been done to respect the NFF 61030 specifications : simultaneous
cruciform stamping with 4 stamps comprising 2 impressions.
Tool insertion
Contact extraction
Retention clip
3 - Contact extraction
4 - Crimping
An extraction tool is available to extract the
contacts. The tool is engaged by the front face of
the connector and the contacts are rear released.
Note : Full wiring instruction form available upon request.