Hook-up wire, Test lead wire, epr rubber – Northern Connectors Alpha Wire Hook-Up Wire User Manual
Page 30
Advertising
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
402
Wire > Hook-Up Wire
Hook-Up Wire
Test Lead Wire, EPR Rubber
Operating Temperature
• -30°C to +90°C
Voltage Rating
• See table
Materials
• Stranded tinned copper
conductors
• EPR rubber insulation
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Part
No.
Wire Size
Stranding
Insulation
Thickness
Nominal
Diameter
Breakdown
Voltage
(RMS)
Working
Voltage
(RMS)
AWG mm
2
AWG
mm
Inch
mm
Inch
mm
1632
20
0.52
41/36 41 x 0.13 0.040
1.02
0.118
3.00
6000
1500
1635
20
0.52
41/36 41 x 0.13 0.047
1.19
0.132
3.35
12,000
3000
1636
18
0.83 65/36 65 x 0.13 0.045
1.14
0.137 3.48
20,000
5000