Hook-up wire, 300 v, pvc – Northern Connectors Alpha Wire Hook-Up Wire User Manual

Page 4

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

376

Wire > Hook-Up Wire > 300 V

Hook-Up Wire

300 V, PVC

UL AWM 1007, 1581, 1569

VW-1

CSA AWM I A/B FT1

CSA TR-64 FT1

Operating Temperature

• -40°C to +105°C (AWM 1569,

CSA AWM)

• -40°C to +90°C (CSA TR-64)

• -40°C to +80°C (AWM 1007,

1581)

Materials

• Stranded or solid tinned

copper conductor

• PVC insulation

Availability

100 ft (30.5 m)

1000 ft (305 m)

Insulation Colors Z1

1 White

5 Yellow

9 Slate

13 White/Green

17 White/

Orange

29 Yellow/Green

2 Black

6 Blue

10 Violet

14 White/Yellow

18 White/

Slate

30 Pink

3 Red

7 Brown

11 White/Black

15 White/Blue

19 White/

Violet

4 Green

8 Orange

12 White/Red

16 White/Brown

28 Green/

Yellow

Part No.

Wire Size

Stranding

Insulation

Thickness

Nominal

Diameter

Colors

AWG mm

2

AWG

mm

Inch

mm

Inch

mm

3047

30

0.06

7/38

7 x 0.10

0.016

0.41

0.044

1.12

Z1, 1 - 10

3048

28

0.09

7/36

7 x 0.13

0.016

0.41

0.047

1.19

Z1, 1 - 10

3049

26

0.14

7/34

7 x 0.16

0.016

0.41

0.051

1.30

Z1, 1 - 10

3050/1

24

0.20

Solid

1 x 0.51

0.016

0.41

0.052

1.32

Z1, 1 - 10

3050

24

0.23

7/32 7 x 0.20

0.016

0.41

0.056

1.42

Z1, 1 – 19, 28,

30

892407T† 24

0.23

7/32 7 x 0.20

0.016

0.41

0.056

1.42

Z2, 0 - 9

892419†

24

0.24

19/36 19 x 0.13

0.016

0.41

0.057

1.45

Z2, 0 - 9

3051/1

22

0.32

Solid

1 x 0.64

0.016

0.41

0.057

1.45

Z1, 1 - 10

3051

22

0.35

7/30 7 x 0.25

0.016

0.41

0.062

1.57

Z1, 1 – 19, 28,

30

892207T† 22

0.35

7/30 7 x 0.25

0.016

0.41

0.062

1.57

Z2, 0 - 9

892219†

22

0.38

19/34 19 x 0.16

0.016

0.41

0.064

1.63

Z2, 0 - 9

3053

20

0.51

10/30 10 x 0.25 0.016

0.41

0.069

1.75

Z1, 1 – 19, 28,

30

892010T†

20

0.51

10/30

10 x 0.25 0.016

0.41

0.069

1.75

Z2, 0 - 9

3053/1

20

0.52

Solid

1 x 0.81

0.016

0.41

0.064

1.63

Z1, 1 - 10

892007†

20

0.56

7/28

7 x 0.32

0.016

0.41

0.070

1.78

Z2, 0 - 9

892019†

20

0.62

19/32 19 x 0.20 0.016

0.41

0.072

1.83

Z2, 0 - 9

3055

18

0.81

16/30 16 x 0.25 0.016

0.41

0.079

2.01

Z1, 1 – 19, 28,

30

891816T†

18

0.81

16/30 16 x 0.25

0.016

0.41

0.079

2.01

Z2, 0 - 9

3055/1

18

0.82

Solid

1 x 1.02

0.016

0.41

0.072

1.83

Z1, 1 - 10

891819†

18

0.96

19/30 19 x 0.25 0.016

0.41

0.082

2.08

Z2, 0 - 9

3057/1

16

1.31

Solid

1 x 1.29

0.016

0.41

0.083

2.11

Z1, 1 - 10

3057

16

1.32

26/30 26 x 0.25 0.016

0.41

0.092

2.34

Z1, 1 – 19, 28,

30

891441†

14

2.08

41/30 41 x 0.25 0.016

0.41

0.106

2.69

Z2, 0 - 9

891265*†

12

3.30

65/30 65 x 0.25 0.016

0.41

0.125

3.18

Z2, 0 - 9

891000*†

10

5.32

105/30 105 x 0.25 0.016

0.41

0.150

3.81

Z2, 0 - 9

*UL AWM 1581 and 1569. All others UL AWM 1007 and 1569.
†CSA AWM I A/B FT-1.
“T” indicates topcoat conductors.

Insulation Colors Z2

0 Black

4 Yellow

8 Slate

1 Brown

5 Green

9 White

2 Red

6 Blue

3 Orange

7 Violet

These wires also available in 500 ft (152 m) put-ups.

Advertising