Technical Data

Insulator

Contacts

Contact plating

Shell

Dielectric with standing voltage

Working voltage

Contact resistance

Insulation resistance

Current rating

Voltage surge 10 700µs

Temperature working range

Capacitor values
For other capacitance values please contact the factory.

Mating and unmating forces

Quality class

Degree of protection

Materials

Polyester GF UL94 V-0

CU alloy

Gold plated over nickel, solder area tin plated

Brass tin plated Stainless steel

Standard

424 VDC

Standard

300 VDC

100 VDC

100 VDC

Depending on isolation coordination (refer to DIN VDE 0110 IEC 664-1)

Max. 10 mΩ prior to stressing, Δ R max. 10 mΩ after stressing

per DIN 41652, Part 2

≥ 1GΩ

7.5 A (UL) 5 A (CSA, VDE)

3 A (UL, VDE) 2.5 A (CSA)

Standard

300 V

Standard

300 V

-25°C to +105°C

-25°C to +85°C

180 pF ± 20% tolerance

180 pF ± 20% tolerance

370 pF ± 20% tolerance

370 pF ± 20% tolerance

830 pF ± 20% tolerance

830 pF ± 20% tolerance

1300 pF ± 20% tolerance

9 pos. ≤ 30 N

15 pos.

≤ 50 N

15 pos. ≤ 50 N

26 pos.

≤ 84 N

25 pos. ≤ 83 N

44 pos.

≤ 120 N

37 pos. ≤ 123 N

62 pos.

≤ 170 N

50 pos. ≤ 167 N

A = Quality class 3 = 50 mating cycles

B = Quality class 2 = 200 mating cycles

C = Quality class 1 = 500 mating cycles

Requirement according to IEC 60529 – IP67

Filter D-SUB Standard

9, 15, 25, 37 and 50 position

Filter D-SUB High Density

15, 26, 44, and 62 position

Mechanical and electrical