Characteristics, 8 to 12-9, N 50 ω – Northern Connectors Radiall N Series Coaxial Connectors User Manual

Page 8: Characteristics electrical characteristics, Mechanical characteristics

Advertising
background image

www.radiall.com

12-8

N 50

Ω

CHARACTERISTICS

ELECTRICAL CHARACTERISTICS

Impedance

50Ω

Frequency range

DC - 11 GHz

Typical V.S.W.R. Frequency

straight models cable group: .085"

.141"
.250"
5/S+5/D
10/S+11/D

right angle models: 5/S+D

10/S+11/D

1 GHz

1.03
1.03
1.03
1.05
1.04
1.04
1.04

2.5 GHz

1.03
1.05
1.03
1.06
1.05
1.05

1.1

5 GHz

1.05
1.05
1.05

1.1

1.09

1.18

1.20

11 GHz

1.08
1.08

1.07
1.16

1.2

Intermodulation product (IMP

3

)

• Standard connectors
• Intermodulation connectors
• Home made intermodulation cable assemblies

- 90 dBm typ. (- 133 dBc typ. / 20W)

- 110 dBm typ. (- 153 dBc typ / 20W)

- 125 dBm typ. (- 165 dBc typ. / 20W)

Insertion loss straight connector
right-angle connector

MIL

< 0.15 dB max at 10 GHz ~ < 0.05 √F (GHz)

< 0.15 dB max at 10 GHz ~ < 0.1 √F (GHz)

RF Leakage

MIL

-90 dB min from 2 to 3 GHz (interface)

Insulation resistance

MIL

5000 MΩ min

Contact resistance

center contact
outer contact

MIL

Initial

1 mΩ

0.2 mΩ

After tests

1.5 mΩ

-

Working voltage in VRMS

at sea level
(at 70, 000 feet)

CECC

Cable 5/50: 850 (250)
Cable .085”/.141”:

350 (250)

Cable 10+11/50:

1400 (400)

Cable LMR 400/600:

1400 (400)

Cable .250”:

1400 (400)

Dielectric withstanding voltage in VRMS

at sea level
(at 70, 000 feet)

CECC

Cable 5/50: 1500 (350)
Cable .085”/.141”:

1000 (350)

Cable 10/50:

2500 (600)

Cable LMR 400/600:

2500 (600)

Cable .250”:

2500 (600)

RF testing voltage sea level

CECC

1500 VRMS (5 MHz sine wave)

MECHANICAL CHARACTERISTICS

Durability

CECC

500 matings

Engagement and separation torque

CECC

6.6 Ncm max (.58 Inch-pounds)

Recommended coupling nut torque

40 to 60 Ncm (manual)

130 Ncm (11.45 inch pounds) (with pliers R 282 202 000)

170 Ncm (14.96 inch pounds) (with torque wrench R 282 303 020)

Proof torque

CECC

170 Ncm (14.96 inch pounds)

Coupling nut retention force

CECC

450 N (101.25 Lbs)

Cable retention force

CECC

Cable 5/50/S

150 N (33.75 Lbs)

Cable 5/50/D

200 N (48 Lbs)

Cable 10/50

300 N (67.5 Lbs)

Cable 11/50

400 N (90 Lbs)

Cable .141”

270 N (60.75 Lbs)

Center contact retention force axial

MIL

27 N (6.08 Lbs) cables <  8 mm
68 N (15.30 Lbs) cables >  8 mm

Test/characteristics

Standard reference

Values/remarks

Standard packaging = 50 pieces.

Advertising