Technical data measurement microphones, Specifications – NTi Audio M2230-WP User Manual

Page 22

Advertising
background image

22

Specifications

Technical Data Measurement Microphones

M2230

Class 1 Certified

M2230-WP

Class 1

Outdoor

Microphone

(M2230+WP30)

M2211

Frequency

Response

Class 1

M2215

High SPL

Frequency

Response

Class 1

M4260

Class 2

Microphone Type

Omnidirectional, pre-polarized condenser,

free field microphone

Classification according

IEC 61672 and ANSI S1.4

Class 1 / Type 1

Certified

Class 1 / Type 1

Frequency Response

Class 1 / Type 1

Class 2 / Type 2

Capsule / Transducer

1/2” detachable with 60UNS2 thread,

type WS2F according IEC 61094-4

1/4” permanently installed

PreAmplifier Type

MA220

-

Flatness tolerance bands

typical

±1 dB @ 5 Hz - 20 Hz

±1 dB @ >20 Hz - 4 kHz

±1.5 dB @ >4 kHz - 10 kHz

±2 dB @ >10 kHz - 16 kHz

±3 dB @ >16 kHz - 20 kHz

+1/-4.5 dB @ 5 Hz - 20 Hz

±1.5 dB @ >20 Hz - 4 kHz

±3 dB @ >4 kHz - 10 kHz

±4.5 dB @ >10 kHz - 16 kHz

±5 dB @ >16 kHz - 20 kHz

Frequency Range

5 Hz - 20 kHz

Residual Noise Floor typical

16 dB(A)

21 dB(A)

25 dB(A)

29 dB(A)

Maximum SPL

@ THD 3%, 1 kHz

139 dBSPL

144 dBSPL

153 dBSPL

144 dBSPL

Sensitivity typical @ 1 kHz

-27.5 dBV/Pa ±2 dB

(42 mV/Pa)

-34 dBV/Pa ±3 dB

(20 mV/Pa)

-42 dBV/Pa ±3 dB

(8 mV/Pa)

-31.7 dBV/Pa ±3 dB

(26 mV/Pa)

Temperature Coefficient

< -0.01 dB / °C

< ±0.015 dB / °C

< ±0.02 dB / °C

Advertising