Opticon XPT 3125 Universal menubook User Manual

Page 52

Advertising
background image

Code options

3

OPTICON Universal menu book

U45

Serial programming:
To set a length using serial commands, the
sequence is as follows:
<ESC>
<command>
<SPACE>*<CodeID>*
<Length 1>
<Length 2**>
<CR>
*(if required by <command>)
**(length 2 may be the same length as length 1,
when only one length is required)

Example:
Setting fixed length for all codes, lengths 8, 10
and 12:
• <ESC>H1081012<CR>
Setting minimum length for selected codes, for
Code 39 with a length of 2:
• <ESC>HL V02<CR>
Setting maximum length for selected codes, for
Code 39 with a length of 12 and Interleaved
2of5 with length of 14:
• <ESC>HM V12 N14<CR>

3.2. Setting of number of characters

SET

_ZZ_

Fixed length OFF all
codes

H0

_H0_

Fixed length ON all
codes

H1

_H1_

Fixed length ON for
selected codes

HK

_HK_

Minimum length for
selected codes

HL

_HL_

Maximum length for
selected codes

HM

_HM_

END

_ZZ_