Step 10 - fitting the batteries, Step 9 - wiring (contact switch option) – Paxton Net2 PaxLock - Scandic User Manual
Page 3

Page 3
Present the front lock assembly to the door passing
the wiring harness through the 16 mm hole.
Present the rear lock assembly to the door and join
the two parts together with the two mounting screws.
Optional cover plates are provided if required. To fit,
position flush to the door then place and join each
lock assembly over the top as described in step 7.
Step 7 - Mounting on the door
Step 6 - Optional cover plates
Step 8 - Wiring
Plug the wiring harness into the socket in the rear
lock assembly.
Clip in the 4 x AA alkaline batteries with reference to
the label displayed below the holder assembly.
Make sure to clip the batteries over the ribbon
to make the removal of the batteries easier.
Step 10 - Fitting the batteries
Where a contact switch is fitted, connect the wires to
the terminal block provided.
Step 9 - Wiring (contact switch option)
Mounting screws are provided in three lengths.
Short - Door width 35 mm to 45 mm
Med
- Door width 40 mm to 50 mm
Long - Door width 45 mm to 60 mm