Exit, Wiring to a compact reader wiring – Paxton Marine exit button User Manual
Page 4
12V DC
power supply
Electric release
The green LED on the exit button is illuminated
but will not flash when used with compact readers.
The declaration of conformity is available on request. Contact details are provided at:
http://paxton.info/596
-25 °C
+55 °C
8V DC
14V DC
220 mA
106 mm
16 mm
Voltage
Specifications
Operating temperature
Electrical
Environment
Current
Cable length
Outdoor Use
Dimensions
Min
Diameter
Max
Min
Max
Depth
This unit uses solid state electronics to switch 0V to the Exit 0V output and
therefore cannot be used with circuits that require voltage free contacts.
5 metres
No
THIS UNIT IS FOR INTERNAL USE ONLY.
This Exit button unit is designed to complement the PROXIMITY Marine reader. It has no moving parts and is
waterproof to IPX7.
The use of capacitive sensing to determine the presence of a user’s finger does, however, make it unsuitable for
external use. The reason for this is that heavy rainfall / snow / etc. could activate the exit button in error.
0V
+12V
+12V
0V
EXIT
Exit 0V
Green LED
+12V DC
0V
Wiring to a Compact reader
Wiring