Safety requirements, Specifications – Paxton Net2 I/O board User Manual

Page 7

Advertising
background image

Only qualified Engineers should install and service this equipment.

Read the instructions before installing and powering the equipment. Adhere to all instructions or warnings. Keep

the instructions in a safe place for future reference.

The equipment is intended for indoor use only in dry locations.

The installation must meet the requirements of National Wiring Regulations and IEC60950-1.

Considerations shall be made with regard to the positioning of equipment to ensure all required creepage and

clearance limits are met. Creepage is the shortest path between two conductive parts measured along the surface

of the insulation and clearance is the shortest distance between two conductive parts measured through air.

Enclosures used must be selected with regard to Fire resistance to suit the end installation.

The 12V DC supply to the unit shall meet the requirements of IEC60950-1 and SELV (Safety Extra Low Voltage).

The supply should have appropriate current rating to power the I/O board (min 300 mA) and any other loads.

If the power supply shows signs of damage or malfunction, immediately stop use (disconnect from mains if

applicable) and contact the supplier for repair or replacement.

The mains cable shall be away from SELV cables unless mains wiring has a distance through insulation of 0.4 mm.

The routing of the cables should be away from rough or sharp objects to avoid abrasion with no kinks and

positioned to reduce strain. The cross sectional area of the cables should be within the parameters of acceptance

for the terminal connectors and suitable for application.

Considerations shall be made with regard to fuse protection to output relays and equipment being driven by the

relay. This must be appropriate in terms of current rating and fusing characteristics for application, be high braking

capacity and approved in accordance with IEC 60127 or an appropriate circuit breaker approved in accordance with

IEC 60947.

Safety Requirements

*This max value is for when all four relays are energised

Voltage

4
4

240V AC

13 A

4 kV AC

10 Mbit/s

100 Mbit/s

11V DC

14V DC

200 mA

400 mA *

-20 °C

+55 °C

114 mm

120 mm

32 mm

175 mm

170 mm

40 mm

236 mm

320 mm

80 mm

Operating temperature

Electrical

Environment

Dimensions

Min

Max

Width

Depth

Current

NO - If used externally, it must be protected in a plastic weatherproof housing

Features

Relay contact isolation

Relay voltage rating

Circuit board in plastic housing

Circuit board

Circuit board in 2A power supply cabinet

Ethernet network speed
DHCP support (fixed IP recommended)

Waterproof

Relay current rating

Relay inputs
Relay output

Specifications

Auto Select

Min

Min

Max

Max

Height

Yes