Webcctv user manual – Quadrox WebCCTV User Manual User Manual

Page 65

Advertising
background image

WebCCTV User Manual

65

Version 4.9 Series

3.3.2.5.4 FTP

The FTP upload function enables automatic uploading of the movies and images, which were
created based on an incoming alarm, onto a remote FTP server or to a local folder for further
revision and storing. To configure FTP uploading, see 3.3.7.2 FTP Parameters.

An alarm image is a snapshot captured at the moment the alarm is triggered.

To use this feature, select the corresponding checkbox.

FTP (Alarm) Screen

Click Next to enter the next Alarm Configuration Wizard Screen.

3.3.2.5.5 Outputs

This tab allows you to configure which outputs will send the signals to the external devices
when an alarm is triggered.

The output tab is only available if some lines of the I/O device are set as output.

To configure outputs follow the steps below:

1. Select the output from the corresponding drop – down list.
2. Select the state to which the output will switch when an alarm is triggered.

By default the output is in Low State. This means that the voltage on the
corresponding pin is 0 V. When an alarm is triggered, the output switches to the High
State which corresponds to the voltage of 5 V.

3. Choose when the output will return to its previous state. There are two variants:

 Output returns to its previous state in a time span you indicate.
 Output returns to its previous state on the deactivation of the triggered alarm.

4. Click Add Output button.

Advertising