01Series Operator’s Manual

Operation • 14

Resetting Gas Alarms

To reset a gas alarm, press the POWER/MODE button after the gas
reading falls below the low alarm point. If a TWA or STEL alarm has been
activated, it cannot be reset unless you turn off the unit.

NOTE: Even though the gas concentration may have returned to normal

or may have fallen below the low alarm point, the alarm
indications will continue until you have reset the alarm using the
POWER/MODE button.

Over Range
Concentration of gas
rises above the
measuring limit of the
01 Series. (Or there
could be a problem
with the unit.)

• Gas reading

replaced by blinking
brackets.

• Back light turns on.

• Pulsing tone occurs

once per second.

• Unit vibrates once

per second.

• Alarm light flashes.

Low Battery Warning

• Last remaining bar

on the right in
battery icon
flashes.

• None

Dead Battery Alarm

• Gas reading

replaced by FAIL.

• Battery icon

flashes.

• Double pulsing tone

(two pulses in quick
succession) occurs
once a second.

Sensor Failure

• Gas reading

replaced by FAIL.

• Double pulsing tone

(two pulses in quick
succession) once a
second.

System Failure

• Gas reading

replaced by FAIL.

SYS displays below

FAIL.

• Double pulsing tone

(two pulses in quick
succession) once a
second.

Table 3: Alarm Types and Indications

Alarm Type

LCD Indications

Other Indications