Replacing the sensor – RKI Instruments 01 Series Manual User Manual

Page 29

Advertising
background image

01Series Operator’s Manual

Maintenance • 24

3. Rotate the captive battery cover screw counterclockwise to remove

battery compartment door.

4. Carefully remove the old alkaline batteries.

5. Carefully install the new AAA alkaline batteries. Follow the battery

diagram inside the battery compartment.

6. Reinstall the battery cover.

NOTE: If the unit has been without batteries or if the old batteries have

been dead for an extended period, allow 10 minutes after the new
batteries have been installed for the sensor to stabilize.

Replacing the Sensor

WARNING: Replace the sensor in a non-hazardous environment.

1. Verify that the 01 Series is off.

2. Remove the sensor end protective rubber boot.

3. With a small Phillips screwdriver, carefully unscrew the two screws that

hold the sensor retainer in place.

POWER MODE

AIR

CO-01

CO

Figure 6: Removing the Battery Compartment Door

Sensor Retainer

Sensor

POWER

MODE

AIR

CO-01

CO

Figure 7: Removing the Sensor Retainer

Advertising