61-1004RK/61-0191RK Carbon Dioxide Detector • 1

Overview

This manual describes the 61-1004RK CO

2

(carbon dioxide) detector. This manual also

describes how to install, start up, maintain, and calibrate the detector when used with a
gas monitoring controller. A parts list at the end of this manual lists replacement parts and
accessories for the CO

2

detector.

The 61-1004RK CO

2

detector includes the 61-0191RK detector and a junction box. This

manual may also be used for the 61-0191RK CO

2

detector which does not include a

junction box and is normally mounted in one of a controller’s conduit hubs and factory
wired to the controller. If you are using a 61-0191RK CO

2

detector, disregard all references

to the junction box and junction box terminal block.

Specifications

Table 1 lists specifications for the CO

2

detector.

WARNING: When using the 61-1004RK, you must follow the instructions and warnings

in this manual to assure proper and safe operation of the 61-1004RK and to
minimize the risk of personal injury. Be sure to maintain and periodically
calibrate the 61-1004RK as described in this manual.

Table 1: 61-1004RK Specifications

Detection Range

With Junction Box
61-1004RK-02: 0 - 5,000 ppm CO

2

61-1004RK-03: 0 - 5% Volume CO

2

61-1004RK-05: 0 - 50% Volume CO

2

61-1004RK-10: 0 - 100% Volume CO

2

Without Junction Box
61-0191RK-02: 0 - 5,000 ppm CO

2

61-0191RK-03: 0 - 5% Volume CO

2

61-0191RK-05: 0 - 50% Volume CO

2

61-0191RK-10: 0 - 100% Volume CO

2

Area Classification

Explosionproof for Class I, Groups B, C, and D

Sampling Method

Diffusion

Response Time

90% in 45 seconds

Accuracy

± 5% of reading or ± 2% of full scale (whichever is greater)