Overview

This manual describes the 61-1007RK CO

2

(carbon dioxide) detector. This manual also

describes how to install, start up, maintain, and calibrate the detector when used with a
gas monitoring controller. A parts list at the end of this manual lists replacement parts and
accessories for the CO

2

detector.

The 61-1007RK CO

2

detector includes a junction box. This manual may also be used for

the 61-0198RK CO

2

detector which does not include a junction box and is normally

mounted in one of a controller’s conduit hubs and factory wired to the controller. If you
are using a 61-0198RK CO

2

detector, disregard all references to the junction box and

junction box terminal block.

Specifications

Table 1 lists specifications for the CO

2

detector.

WARNING: When using the 61-1007RK, you must follow the instructions and warnings

in this manual to assure proper and safe operation of the 61-1007RK and to
minimize the risk of personal injury. Be sure to maintain and periodically
calibrate the 61-1007RK as described in this manual.

Table 1: 61-1007RK Specifications

Detection Range

With Junction Box
61-1007RK-02: 0 - 5,000 ppm CO

2

61-1007RK-03: 0 - 5% Volume CO

2

61-1007RK-05: 0 - 50% Volume CO

2

61-1007RK-10: 0 - 100% Volume CO

2

Without Junction Box
61-0198RK-02: 0 - 5,000 ppm CO

2

61-0198RK-03: 0 - 5% Volume CO

2

61-0198RK-05: 0 - 50% Volume CO

2

61-0198RK-10: 0 - 100% Volume CO

2

Sampling Method

Diffusion

Response Time

90% in 45 seconds

Accuracy

± 5% of reading or ± 2% of full scale (whichever is greater)