65-2437RK-05 CO Detector • 3

65-2433RK-05 CO Detector

The 65-2433RK-05 CO detector consists of the detector housing body, detector housing
cap, cap gasket, the plug-in sensor, and the charcoal filter with rubber boot.

Figure 2: CO Detector Component Location

Detector Housing, Housing Cap, & Cap Gasket

The detector housing body protects the sensing components within the housing. Use the
3/4” NPT mounting threads at the top of the housing to screw the CO detector into the
bottom conduit hubs of the junction box. Use the removable cap near the bottom of the
housing to access the sensor for maintenance or replacement. The cap protects the sensor
from damage and includes a flame arrestor which contains any sparks which may occur
within the detector housing. A cap gasket seals the interface between the housing and cap.
A flame arrestor guard is permanently bonded to the cap.

Two wires extend from the top of the detector housing body. Use these wires to connect
the CO detector to the junction box terminal strip. The housing includes a four-socket
pattern. This socket pattern accepts the sensor’s four pins to secure the sensor within the
detector housing. A pre-amplifier, located between the sockets and two interconnect
wires, conditions the sensor’s signal before the signal reaches the controller.

Plug-In Sensor

The sensor is secured within the sensor housing by four pins. Through a series of chemical
and electrical reactions, the sensor produces an electrical output that corresponds to the
detection range of the detector.

Charcoal Filter

The disc-shaped charcoal filter is secured to the face of the CO sensor with a rubber boot.
The charcoal filter prevents interference gases (hydrogen sulfide [H

2

S] and certain

hydrocarbons) from producing false CO readings.

Detector Housing Cap

Rubber Boot With
Charcoal Filter

Plug-In CO Sensor

Cap Gasket

Detector Housing Body

Flame Arrestor
Guard