in the gas line) may require the unit to be turned off and immediately back on
numerous times after each lockout period until the air is purged from the gas line.


B. SHUTDOWN

STANDBY


1. Place power on switch and thermostat to “OFF” position.


COMPLETE

1.

Place power on switch and thermostat to “OFF” position.

2. Turn dial

on combination control from “ON” position to “OFF” position.

3.

Turn any main gas service valves supplying gas to “OFF” position.

RELIGHTING

1.

Turn power switch to “ON” position.

It should be noted that the pilot and electronic ignition do not cycle with the thermostat. A
standing pilot is automatically established and monitored each time the power switch is
turned ON. If the pilot is ever extinguished by a momentary external interruption, the spark
igniter will automatically relight it without disturbing the cooking cycle, unless lockout occurs.