6.0 SERVICE

WARNING: Disconnect unit from power supply before cleaning or
servicing appliance.


GENERAL

When any difficulty arises always check that the unit has been connected to the gas supply type
and voltage for which it was supplied. This can be done by examining the serial plate on the
lower right side of the unit. It will list the gas type and voltage for which the unit was
manufactured.

Wiring diagrams for the unit are located in a small envelope affixed to the rear side of the front
control panel.

Orifice Size

Unit

Total Input

Natural

Propane

KLS-20G

100,000 BTU/Hour

29

44

KLS-40G

100,000 BTU/Hour

29

44

KLS-60G

130,000 BTU/Hour

23

39


MANIFOLD PRESSURE

Natural Gas - 4 inches W.C.

LP Gas - 10 inches W.C.


PILOTS

The pilot adjustment is part of the combination control valve located just behind the lower front
access door. It is located on the centre left side of the control just below the large slotted screw
head. (See Figure 1). Remove the large slotted screw; below this is a second slotted screw
used for adjustment of the pilot burner flame.

Figure 1
Top view of gas control