Tube kits (not emissive coated) – Schwank 2-Stage Series User Manual

Page 43

Advertising
background image

43

SET(U)-F / ITT(U)-F Manual

IM091221

RD: FEB 2014

RL: 8B

Tube Kit Shipping

Weight (lbs)

120

170

210

165

165

120

165

Nominal Length (ft)

20'

30'

40'

30'

30'

20'

30'

MODEL

TM-1420-

SX

TM-1430-

SX

TM-1040-

SX

TM-F030-

SX

TM-1030-

SX

TM-0020-

SX

TM-0030-

SX

20'

1

30'

1

30'

1

40'

1

30'

1

40'

1

40'

1

50'

1+

1

1

50'

1+

1

60'

1+

1

50'

1+

1

60'

1+

1

TUBE KITS (Not emissive coated)

Stand-Alone tube kits require no additional tube kits.

Primary tube kits require at least one additional Secondary tube kit.

Secondary tube kit require a Primary tube kit.

'SET / ITT' TUBE KIT PART # & QUANTITY REQUIRED

Stand-Alone Kits

Primary Kits

Secondary Kits

80/60

110/75

130/90

155/110

175/125

200/140

25A. BURNER & TUBE KIT ASSEMBLY CHART MODELS SET / ITT

MODELS SET & ITT are approved for indoor commercial / industrial non-residential applica-

tions. For outdoor, wet and harsh environment applications refer to models SPW-JZ / IWP

(powder coated burner box) and/or STW-JZ / IW (stainless steel burner box).

BEFORE INSTALLING: ENSURE you have the CORRECT TUBE KIT(s) for the

BURNER INPUT

USA - Stainless Steel Flexible Gas Connector

130,000 or less:
JL-0771-XX - 1/2”x24”

155,000 or more:
JL-0771-YY - 3/4”x36”

FLEXIBLE GAS CONNECTOR (Included in Burner Kit) - MUST INSTALL - see Section 13

CANADA - Type 1 Hose Gas Connector

130,000 or less:
JL-0771-RC - 1/2”x36”

155,000 or more:
JL-0771-RB - 3/4”x36”

Advertising