GP-MSEM-BX-06A

SEM(U) / IT(U) Manual

RD: Aug 2006

RL: 06A

KH

TABLE 4


MODEL

TURBULATOR

LENGTH

(IF REQUIRED)

SEM/IT 200-70/60/50

10’

SEM/IT 175-70/60/50

10’

SEM/IT 155-60/50

not required

SEM/IT 155-40

10'

SEMU/ITU 155-30

not required

SEMU/ITU 155-20

10’

SEM/IT 130-50

not required

SEM/IT 130-40

10'

SEM/IT 130-30

14'

SEMU/ITU 130-20

10’

SEMU/ITU 130-15

14’

SEM/IT 110-50

not required


MODEL

TURBULATOR

LENGTH

(IF REQUIRED)

SEM/IT 110-40

10'

SEM/IT 110-30

14'

SEMU/ITU 110-20

10’

SEMU/ITU 110-15

14’

SEM/IT 100-20

10’ S/S

SEM/IT 80-40

10’

SEM/IT 80-30

14'

SEM/IT 80-20

14'

SEMU/ITU 80-15

14’

SEMU/ITU 80-10

14’

SEM/IT 60-30

14’

SEM/IT 60-20

14’

SEMU/ITU 60-10

14’

NOTE: Where required the SEMU/ITU Series Heaters will be supplied with the turbulators,
snugly installed into the vent end tube (s) of the system configuration.

FIGURE 12 REFLECTOR ARRANGEMENTS

FIGURE 10 MOUNTING REFLECTOR END CAP

1

Reflector End Cap Flange
protruding over and under
the Reflector

2

Screws securing Reflector
to End Cap

3

Opening for Tube

4

Focus Shield Reflector

1

4

3

2

Page 12