IS THERE VOLTAGE FROM IGNITION
CONTROL TO COMBINATION GAS
VALVE?

→CHECK ELECTRICAL WIRES FROM IGNITION
CONTROL TO COMBINATION GAS VALVE
→CHECK IGNITION CONTROL, REPLACE IF
NECESSARY

NO

IS GAS COMING THROUGH
ORIFICE ON THE HEATER?

YES

→ENSURE ALL GAS VALVES ARE OPEN

NO

YES

DOES THE IGNITION CONTROL
TERMINATE THE SPARKING
PROCESS AFTER 21 SECONDS.

→CHECK SPARK IGNITER FOR CRACKS,
REPLACE SPARK IGNITER IF NECESSARY
→REPLACE WITH NEW IGNITION CONTROL
UNIT IF NECESSARY

STILL HAVING TROUBLE
OPERATING THE HEATER?

→REPEAT THE ABOVE TROUBLE SHOOTING
PROCEDURES
→IF THE PROBLEM PERSISTS, CONTACT YOUR
DISTRIBUTOR.

YES

YES

NO

NO