PERFORMANCE DATA (cont)

COOLING CAPACITIES (cont)

LEGEND

NOTES:

1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:

t

lwb

= Wet-bulb temperature corresponding to enthalpy of air leaving evapo-

rator coil (h

lwb

)

Where: h

ewb

= Enthalpy of air entering evaporator coil

3. The SHC is based on 80 F edb temperature of air entering evaporator coil.

Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.

Interpolation is permissible.
Correction Factor = 1.10 x (1 – BF) x (edb – 80).

551A155 (13 TONS) UNITS WITH PERFECT HUMIDITY™ OPTION

Temp (F)

Air Entering

Condenser

(Edb)

Evaporator Air Quantity — Cfm/BF

3600/0.03

4375/0.04

5000/0.05045

5625/0.06

6250/0.07

Evaporator Air — Ewb (F)

62

67

72

62

67

72

62

67

72

62

67

72

62

67

72

75

TC

139

153

130

144

153

135

145

155

138

147

159

145

149

156

SHC

81

63

111

93

68

118

98

68

125

104

72

135

109

72

kW

8.0

8.2

7.9

8.3

8.2

7.9

8.1

8.3

8.0

8.2

8.3

8.3

8.2

8.3

85

TC

133

142

125

137

146

129

138

146

132

140

148

135

142

148

SHC

75

56

105

84

61

113

93

62

120

98

66

125

100

67

kW

8.9

9.1

8.8

9.2

9.2

8.8

9.0

9.0

8.8

9.0

9.2

9.1

9.1

9.3

95

TC

126

135

119

129

137

123

132

139

125

133

139

128

135

139

SHC

70

52

99

78

56

106

84

59

112

90

60

117

95

61

kW

9.9

10.1

9.7

9.9

10.1

9.9

10.0

10.2

9.9

10.1

10.1

9.9

10.1

10.1

105

TC

105

119

127

110

122

130

113

124

130

115

125

131

118

126

132

SHC

80

65

47

92

73

51

97

78

52

104

83

55

108

89

57

kW

10.6

10.9

11.1

10.8

11.0

11.2

10.9

11.0

11.1

10.8

11.0

11.2

10.9

11.1

11.3

115

TC

90

108

119

97

112

121

97

115

122

100

116

123

106

118

123

SHC

66

57

41

79

66

45

80

72

47

88

76

49

95

80

51

kW

11.7

12.1

12.3

11.8

12.2

12.4

11.8

12.3

12.5

12.0

12.4

12.5

12.1

12.3

12.5

117

TC

86

100

111

98

112

121

99

114

121

102

116

123

107

117

123

SHC

64

52

38

63

58

45

67

61

47

72

63

48

77

66

50

kW

12.8

13.2

13.6

12.0

12.3

12.5

12.0

12.3

12.5

11.9

12.4

12.5

12.1

12.4

12.5

120

TC

90

102

114

90

107

117

91

109

118

93

111

119

99

113

119

SHC

67

52

38

71

61

41

76

66

44

81

70

46

87

75

47

kW

12.3

12.6

12.8

12.3

12.7

12.9

12.3

12.8

12.9

12.3

12.8

13.0

12.5

12.9

13.0

125

TC

83

95

109

85

97

112

87

103

113

88

105

114

90

107

114

SHC

61

47

35

66

53

38

72

61

41

76

66

44

78

70

45

kW

12.8

13.1

13.5

12.8

13.1

13.5

12.9

13.3

13.5

12.8

13.4

13.6

12.9

13.4

13.6

551A180 (15 TONS) UNITS WITH PERFECT HUMIDITY OPTION

Temp (F)

Air Entering

Condenser

(Edb)

Evaporator Air Quantity — Cfm/BF

4500/0.02

5250/0.03

6000/0.03905

6750/0.04

7500/0.05

Evaporator Air — Ewb (F)

62

67

72

62

67

72

62

67

72

62

67

72

62

67

72

75

TC

185

203

175

191

209

179

195

212

182

198

213

186

200

216

SHC

105

82

141

115

88

154

125

96

165

135

104

174

145

109

kW

11.3

11.7

11.0

11.4

11.8

11.1

11.5

11.9

11.2

11.6

11.9

11.3

11.7

12.0

85

TC

176

193

166

183

199

170

186

202

173

189

204

177

190

205

SHC

98

74

134

108

81

145

116

85

156

126

93

162

134

97

kW

12.3

12.7

12.1

12.9

13.4

12.1

12.6

13.5

12.2

12.7

13.5

12.7

12.2

12.7

95

TC

168

182

156

173

187

160

176

191

163

178

194

167

181

196

SHC

91

66

126

100

72

137

108

76

146

116

82

153

125

86

kW

13.7

13.5

13.1

13.6

13.9

13.2

13.6

14.1

13.3

13.4

14.3

13.5

13.9

14.6

105

TC

156

173

145

160

175

148

162

177

151

166

178

154

167

180

SHC

83

59

117

90

62

127

98

66

136

106

70

141

112

74

kW

14.5

15.3

14.2

14.8

15.1

14.4

14.5

15.1

14.4

14.9

14.9

14.2

14.6

14.9

115

TC

141

156

130

146

160

132

150

162

135

150

164

139

152

166

SHC

72

47

104

79

52

112

86

55

119

93

59

127

100

63

kW

15.6

15.9

15.2

15.8

16.2

15.3

16.1

16.3

15.4

16.0

16.4

15.8

16.1

16.4

118

TC

138

151

126

141

153

129

144

134

145

135

148

SHC

68

43

100

74

46

108

83

120

88

124

96

kW

16.1

16.5

15.7

16.1

16.5

15.8

16.3

16.0

16.3

15.9

16.3

120

TC

134

124

126

SHC

65

99

106

kW

16.2

15.9

16.0

125

TC

SHC

kW

BF

Bypass Factor

Edb — Entering Dry-Bulb
Ewb — Entering Wet-Bulb
kW

Compressor Motor Power Input

ldb

Leaving Dry-Bulb

lwb

Leaving Wet-Bulb

SHC — Sensible Heat Capacity (1000 Btuh) Gross
TC

Total Capacity (1000 Btuh) Gross

t

ldb

= t

edb

sensible capacity (Btuh)

1.10 x cfm

h

lwb

= h

ewb

total capacity (Btuh)

4.5 x cfm

BYPASS
FACTOR

(BF)

ENTERING AIR DRY-BULB TEMP (F)

79

78

77

76

75

under 75

81

82

83

84

85

over 85

Correction Factor

.05

1.04

2.07

3.11

4.14

5.18

Use formula

shown below.

.10

.98

1.96

2.94

3.92

4.90

.20

.87

1.74

2.62

3.49

4.36

.30

.76

1.53

2.29

3.05

3.82

0

T

F

Q

0

04
-0
12

55
1A1

55-

18
0

Advertising