SDC FB4DC User Manual

Security door controls

Advertising
background image

INSTALLATION WIRING DIAGRAM

FB-4 and FB4DC FUSED TERMINAL BOARDS

P:\INSTALLATION INST\Power Supplies\INST-FB-4\INST-FB-4.vsd REV B 08-11 Page 1

The FB-4 provides four (4) individually fused outputs for modular system protection. A 2 amp fuse
is supplied for each of the 4 fused outputs. Determine the load requirement for each output and
change the fuse with a different rating as needed. The output voltage supplied to each output is
the same as the voltage input. The total current required for all of the outputs must not exceed
the power supply output current rating.

The FB4DC includes an integrated full wave bridge rectifier to allow the use of an AC transformer
or a DC power supply to provide a DC output voltage.

12V to 24V

AC or DC

Power In

+

-

+

_

+

_

UN-Fused

Outpu

t

+

_

Fu

se

d

Outputs

+

_

F4

F3

F2

F1

Model
FB-4

4

3

2

1

+

-

12V to 24V

AC or DC

Power Out

12V to 24V

AC or DC

Power In

+

-

+

_

+

_

UN-F

used

Ou

tp

ut

+

_

Fused

Ou

tp

uts

+

_

F4

F3

F2

F1

Model
FB4DC

4

3

2

1

+

-

12V to 24V

DC

Power Out

SECURITY DOOR CONTROLS

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]

Advertising