INSTALLATION
Horizontal Venting with Two (2) 90
o
Elbows
Option V
H + H1
A)
4' Min. 6' Max.
B)
5' Min. 7' Max.
C)
6' Min. 8' Max.
Vertical Venting with Two (2) 90
o
Elbows
Option V
H
V + V1
A)
1' Min. 4' Max. 2' Min.
B)
2' Min. 5' Max. 3' Min.
C)
3' Min. 6' Max. 4' Min.
D)
4' Min. 7' Max. 5' Min.
E)
5' Min. 8' Max. 6' Min.
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
With these options, maximum total
pipe length is 30 feet with minimum
of 6 feet total vertical and maximum
8 feet total horizontal.
Please note minimum 1 foot be-
tween 90
o
elbows is required.