Installation, Remote control installation, Door handle – Regency Classic C34 Small Gas Stove User Manual

Page 31: Remote wall switch, Wall thermostat installation, Final check

Advertising
background image

Regency

®

CLASSIC C34-3 Direct Vent Freestanding Gas Stove

31

INSTALLATION

CAUTION

Any alteration to the product that causes
sooting or carboning that results in dam-
age to the unit is not the responsibility of
the manufacturer and will not be covered
by the warranty.

REMOTE CONTROL

INSTALLATION

Use the Regency

®

Remote Control Kit approved

for this unit. Use of other systems may void
your warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall

to install the receiver (protection from ex-
treme heat is very important)
. Run wires
from the fi replace to that location. Use the
Thermostat Wire Table.

2) Connect the two wires to the gas valve. See

diagram below.

DOOR HANDLE

Attach spring handle by rotating counter clock-
wise onto rod. Ensure that the spring fi ts into
the entire length of the rod.

DO NOT TRY TO TURN

DOOR HANDLE!

IT IS NOT DESIGNED

TO BE MOVED.

CAUTION

Do not wire millivolt remote con-

trol wires to the

120V AC wires

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

REMOTE

WALL SWITCH

1) Run the wire through the opening in the rear

of the unit. Be careful not to damage any
wires.

Note: We recommend a maximum of 15' of

wire but if you wish to go with a longer
run use the Thermostat Wire Table.

2) Connect the wire to the wall switch and install

into receptacle box.

CAUTION

Do not wire millivolt wall switch

for gas appliance to the 120V AC

wires

WALL THERMOSTAT

INSTALLATION

Regency

®

offers an optional programmable

thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.

Connect the wires as per the wiring diagram.
Use the Thermostat Wire Table to determine the
maximum wire length.

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:

1) Clocking the appliance to ensure the cor-

rect fi ring rate (rate noted on label) at 15
minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow
the unit to burn for 15 min. to stabilize.

3) Check for proper draft.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

Thermostat Wire Table

CAUTION

Do not wire millivolt wall thermo-

stat wires to the 120V AC wires

Note: Preferable if the thermostat is in-

stalled on an interior wall.