factorY

Built cHiMneY

When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase and install the

ceiling support package or wall pass-through and "T" section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc.

Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other

obstructions for safety and proper draft operation.

MasonrY

cHiMneY

Ensure that a masonry chimney meets the mini-

mum standards of the National Fire Protection

Association (NFPA) by having it inspected by

a professional. Make sure there are no cracks,

loose mortar or other signs of deterioration and

blockage. Have the chimney cleaned before

the stove is installed and operated. When

connecting the stove through a combustible

wall to a masonry chimney, special methods

are needed.

MasonrY

fireplace

There are listed kits available to connect a stove

to a masonry fireplace. The kit is an adapter

that is installed at the location of the fireplace

damper. The existing damper may have to be

removed to allow installation.

Liner

Listed