Mobile home installation, Installation – Regency Classic S2400 Medium Step Top Wood Stove User Manual

Page 15

Advertising
background image

Regency Freestanding Woodstove

15

MoBile HoMe installation

Once you have properly marked the position of

your unit and the floor protection as outlined in

the Residential Installation items #1 through #8,

a supply of fresh air has to be supplied to your

unit. Cut a minimum 4" (102mm) diameter hole

through your floor protector and the floor directly

under your pedestal base to the outside. Use 4"

(102mm) duct pipe with a mesh grill to pipe fresh

air into the pedestal area. Block off the hole in

the back of the pedestal with the square plate

and the two 1/2" screws provided.

Place your unit in position and secure it to the

floor using two lag bolts 3/8" (10mm) x 3-1/2"

(89mm) through the two holes inside the pedestal

base. It is important to maintain the structural

integrity of the Mobile Home floor, walls and roof

when installing your unit.

For Mobile Home units installed in the U.S. the

unit must be grounded using a #8 ground wire

with approved termination and star washer.

In addition to standard installation instructions

the following requirements are mandatory for

installation in a mobile home.

1) The stove must be permanently bolted to

the floor of the Mobile Home using the floor

screws provided.

2) The stove must have a permanent outside

air source for combustion.

3) The stove must be electrically grounded to

the steel chassis of the Mobile Home.

4) A listed double-wall connector chimney

system, roof thimble, spark arrestor and roof

flashing kit suitable for use in Mobile Homes

must be used.

5) If the chimney exits the Mobile Home at a

location other than through the roof, and exits at

a point 7ft. (2130mm) or less above the ground

level on which the Mobile Home is positioned a

guard or method of enclosing the chimney shall

be fitted at the point of exit for a height up to

7ft. (2130mm).

6) The chimney shall be attached directly to

the room heater and shall extend at least 3 ft.

(914mm) above the part of the roof through

which it passes. The top of the chimney should

project at least 2ft. (610mm) above the highest

elevation of any part of the Mobile Home within

10 ft. (3048mm) of the chimney.

7) The chimney system shall comply with Local

Requirements.

8) Any openings in a chimney guard where

required must not permit the entrance of 3/4"

(19mm) diameter rod.

9) caution: tHe structural inteGritY

of tHe MoBile HoMe roof, floor,

Walls and ceilinG Must Be Main-

tained.

10) Check any other local building code as other

local codes may apply.

11) WarninG: do not install in a sleep-

inG rooM of a MoBile HoMe.

12) Use silicone to create an effective vapour

barrier at the location where the chimney or

other component penetrates to the exterior of

the structure.

installation

caution: at no time use unlabelled

parts, or substitute parts made for another

chimney system.

install as per chimney manufacturer's

installation instructions.

WarninG: operate only with door fully

closed - open feed door to feed fire only.