Maintenance, Digital fireplace burner control removal – Regency Horizon HZO42 Outdoor Gas Fireplace User Manual
Page 36

36
Regency Horizon™ HZO42 Gas Fireplace
MAINTENANCE
DIGITAL FIREPLACE BURNER CONTROL REMOVAL
5. Disconnect the Black sparker wire with black spade connector from CN3.
See Diagram 2 below.
6. Disconnect the white and green On/Off switch wires.
See Diagram 3 below.
7. Disconnect the yellow ground wire with green diagonal stripe for pilot
(CN2). See Diagram 4 below.
8. Disconnect the three valve wires (yellow wire with green stripe).
See Diagram 5 below.
Diagram 1
Diagram 5
Diagram 2
Diagram 3
Green
White
Diagram 4
Pilot Sensor
Wire
Sparker Wire
ON/OFF wires
Ground wire
Valve wire
2. Remove the DFC from the fl oor of the fi rebox by removing 2 screws in
locations shown below to release DFC bracket.
4. Disconnect the Black Pilot sensor wire with Red Spade connector from
the 'ON' on DFBC (Digital fi replace burner control) box.
See Diagram 1 below.
1 Remove 6 screws in locations shown below to access DFC.
6th screw located at back