4 CH0027 SHORE POWER DIRECT SETUP

CH0027 and CH0028 components are shown in Figure 4-1 and referenced in the list
below:

 Item 1: CH0027

 Item 2: UCA0042 Battery / Shore Power Cable

Figure 4-2 CH0027 Shore Power Components

1. Place the CH0027 on a firm surface with the no skid pad down. Secure unit as

necessary.


2. The CH0027 requires convection cooling and has a series of vents in the back. It is

recommended that a 6” space is available at the rear of the unit from the vents to
facilitate cooling.


3. Connect the direct power cable to the Charger Box output connector and connect to

the target end device.


4. If the CH0027 charger is desired to be grounded, attach a ground wire to the ground

stud on the rear of unit. A 12AWG wire or larger is recommended. See figure 3-7


5. Connect the Charger Box to AC or DC power. The Charger Box will then supply

power to the end use device directly at 31-33VDC.

UKT0011 CH0028/CH0027 Battery Box / Charger System Operation Manual