655740

Electra Steer Diagnosis Trouble Code Reading and Code Clearing

1. Verify that your trouble code light is on steady.

2. Next, take your purple or brown wire and connect it to a good clean ground. You will have to make sure it

is a solid ground to get the LED to blink or flicker and you may have to use a jumper wire to extend the
wire’s length. Once you see the LED flicker or blink wait for LED to start blinking a code.

3. The light will flash in a sequence like 1 and then 123. This code flash would be interpreted as a code 13.

The code will repeat itself 3 times and then go to the next code if there is one in the system. You need to
wait until all the codes are read and recorded.

4. Once you know what the codes are you can use this chart to tell where or what the problem may be.

5. Once you have determined what the problem is and make the necessary repairs, you can proceed to clear

the codes by running a jumper wire from the white wire with the single spade connector on it to a good
ground.

6. Verify the ignition is off. Place the white wire to ground. Turn key on, wait 5 seconds and the light should

go out. When the light goes out turn off ignition and remove jumper wire. Once all repairs are made turn
ignition on and see that light proves out normally. This is all there is to it.

Trouble Code

Problem

Diagnosis

41-42-43-44-45-51

Electric motor

Malfunction

Replace Motor Assembly

11-13-14-15

Torque Sensor

Replace Motor Assembly

52-54-55

ECU Malfunction

Change Computer

22

No Engine Input

Change Computer

21-23-24

No Speed Signal

Change Computer

12

Wiring or

Electrical

Verify 12 volts at green wire. Verify good

ground. Soldier all connections. Check

for bad connections or broken wires.


We welcome your suggestions & comments to make this or any of our installations better! If you
have any questions/problems regarding this product please contact us at:

UNISTEER

Performance Products

1555 Enterprise Parkway

Twinsburg OH 44087

800-338-9080

WWW.UNISTEER.COM

Created on 01/08/2008

Last Revised 6/30/2014

Copyright © 2009 by Maval Manufacturing Corporation All rights reserved.

No part of these materials can be reproduced or utilized in any form or by any means, electronic

or mechanical, including photocopying, recording or by any information storage and retrieval

system, without permission in writing from Maval Manufacturing Corporation.

Advertising