Vortex Optics VIPER 2-7X32 - VERSA-PLEX C3 User Manual

Page 7

Advertising
background image

13

12

Indexing Adjustment Dials with Zero Reset

Viper riflescopes feature windage and elevation dials that allow you
to re-index the zero indicator after sight-in without disturbing your
settings. Though not a required process, resetting the windage and
elevation dials allows you to quickly return to your original zero if
temporary corrections are dialed in the field.

Reset the windage and elevation dials in this way:

1. Remove the outer cap.
2. Pull the adjustment dial outward against the spring tension until
it stops.
3. With the dial pulled fully outwards,
rotate the dial to align the “0” with
the etched indicator line on the scope.
4. Release the dial, allowing it to
return to the normal inward position.
5. Replace the turret cap.

m

AintenAnce

Cleaning

The fully waterproof and fogproof Viper riflescope requires very
little routine maintenance other than periodically cleaning the
exterior lenses. The exterior of the scope may be cleaned by wiping
with a soft, dry cloth.

When cleaning the lenses, be sure to use products that are
specifically designed for use on coated optical lenses such as the
Vortex Fog Free cleaning products or LensPen.

• Be sure to blow away any dust or grit on the lenses prior to
wiping the surfaces.

• Use your breath, or a very small amount of water, to remove
dried water spots. Isopropyl alcohol can help remove marks like
fingerprints.

Lubrication

All components of the Viper riflescope are permanently lubricated,
so no additional lubricant should be applied.

Note: Other than removing the turret caps, do not attempt to
disassemble any components of the scope. Disassembling the scope
may void the warranty.

Storage

If possible, avoid storing your scope in direct sunlight or any very
hot location for long periods of time.

Align the “0” with the
indicator line.

Advertising