Weidmuller WAVE Analog PRO Frequency User Manual
Page 10

23
Special range
(frequency generator is required)
Switch 2
Operating mode
1
2
3
4
Special range
1
1
1
1
Special range
(frequency generator is required)
Switch 2
Operating mode
1
2
3
4
Save min.
frequency
0
1
1
1
3.6 Example 3
Input frequency: 20 kHz...50 kHz
Output: 4...20mA
Special range min. frequency
Special range
(frequency generator is required)
Switch 2
Operating mode
1
2
3
4
Save max.
frequency
1
0
1
1
Special range max. frequency
Selecting the special range
Selecting the output
Switch 2
Output
5
6
7
8
4…20 mA
0
1
0
0
ready
• Apply min. frequency to the module.
• Connect the module to the power
supply.
• The LED lights up when the min.
input frequency is measured. The
frequency has been saved when the
LED blinks; the module can be
disconnected from the power
supply.
• Apply max. frequency to the module.
• Connect the module to the power
supply.
• The LED lights up when the max.
input frequency is measured. The
frequency has been saved when the
LED blinks; the module can be
disconnected from the power
supply.