Weidmuller DC/DC CCC LP - with voltage supply on the output side User Manual
Page 5
Advertising
![background image](/manuals/575593/5/background.png)
13
The declarations of conformity are, in accordance with the above-
mentioned EU-Guideline, Article 10, held at the following address
for the relevant authorities:
Weidmüller Interface GmbH & Co.
Postfach 3030
D-32720 Detmold
7
Technical data
Input
Input signal
4 ... 20 mA
Input voltage, max.
7 V
Input current, max.
25 mA
Output
Output signal
0 ... 20 mA or 4 ... 20 mA
or 0 ... 10 V
Load resistance
≤
500
Ω
(0 ... 20 mA, 4 ... 20 mA)
≥
1 k
Ω
(0 ... 10 V)
Accuracy by T
u
= 23 °C
< 0.2 % from end value
Temperature coefficient
≤
250 ppm/K from measured value
Step response time
≤
30 ms (typ. 20 ms)
Cut-off frequency (-3 dB)
≥
15 Hz (typ. 20 Hz)
Advertising