6. Technical Specifications
6.1 Input Specifications

* Input

voltage

max.

Output-

** Output

voltage

*** Output

current

Input current

at full load typ.

Inrush current

max. at +25°C (<2ms)

Efficiency

typ.

Model

range

power Factory Set ±1%

I

out max

115 VAC

230 VAC 115 VAC 230 VAC at 230VAC

CP T SNT 70W 12V

6A & CP T SNT

90W 24V 3.8A

100-240VAC

85-264VAC

(47-63 Hz)

78 Watt

90 Watt

12 VDC

24 VDC

6.5 A

3.75 A

2.0 A

2.1 A

1.0 A

1.0 A

12.0 A

20.0 A

82.0 %

85.0 %

CP T SNT 140W

12V 12A & CP T

SNT 180W 24V

7.5A, 48V 4A

100-120VAC/

220-230VAC

156 Watt

180 Watt

192 Watt

12 VDC

24 VDC

48 VDC

13.0 A

7.5 A

4.0 A

2.5 A

2.8 A

2.8 A

1.4 A

1.5 A

1.5 A

13.0 A

25.0 A

85.0 %

88.0 %

90.0 %

CP T SNT 360W

(24V 15A, 48V 7.5A)

85-132 VAC/

187-264 VAC

360 Watt

360 Watt

24 VDC

48 VDC

15.0 A

7.5 A

5.0 A

5.0 A

2.5 A

2.5 A

16.0 A

25.0 A

87.0 %

89.0 %

CP T SNT 600W

(24V 25A, 48V

12.5A)

(47-63 Hz)

Auto range

600 Watt

600 Watt

24 VDC

48 VDC

25.0 A

12.5 A

10.0 A

10.0 A

5.0 A

5.0 A

25.0 A

30.0 A

89.0 %

91.0 %

* Observe output current derating at operation below an input voltage of 110VAC (see Fig. 4.2).

** Output voltage adjustable 12 - 14VDC, 24 - 28VDC and 48 - 56VDC

*** Maximum current at nominal output voltage (Vout nom) and operating temperature up to +40°C max.

6.2 Output Specifications

Regulation

- Input Variation (Line Regulation)

- Load Variation (Load Regulation)


V

in min

- V

in max

10% - 100% of I

out max

0.5% max

0.5% max

2.0% in parallel operation

Output Voltage adjustable Range

with Potentiometer

12 V Model

24 V Model

48 V Model

12 - 14 VDC

24 - 28 VDC

48 - 56VDC

Ripple and Noise (20MHz Bandwidth) at V

in nom

und I

out max

200mV pk-pk max

Overload protection

Thermal protection

Automatic restart

Electronic Short Circuit Protection

Continuous

Constant current. Automatic restart

Parallel Operation

all Models; User selectable standard mode and

parallel mode by jumper on PCB

up to 5 Power Supplies possible

(Jumper position see Fig. 5.1, 5.2, 5.3 & 5.4)

Over Voltage Protection (OVP)

Trigger point at

20VDC 12VDC units

35VDC 24VDC units

60VDC 48VDC units

Hold-up Time

at full load and V

in

= 115VAC

at full load and V

in

= 230VAC

10ms min.

20ms min

Reverse Voltage Protection

(Power back immunity)

16VDC

35VDC

63VDC

Status Indicator (two colours)

Green LED

Red LED

Normal operation

Output failure – if AC input mains is present

Power Good Signal

Trigger threshold

12VDC units

24VDC units

48VDC units

Active output signals CP T SNT 70W 12V 6A

(referenced to –V

out

) CP T SNT 140W 12V 12A

CP T SNT 90W 24V 3.8A

24VDC units

48VDC units

Relay output DC-OK = Contact closed

9 – 11 VDC

18 – 22 VDC

36 - 44 VDC
11.0VDC ±1.0VDC / 20mA max.

11.0VDC ±1.0VDC / 40mA max.

22.0VDC ±2.0VDC / 10mA max.

22.0VDC ±2.0VDC / 20mA max.

44.0VDC ±4.0VDC / 15mA max.
30VDC / 1.0A max. for 12 / 24VDC models

48VDC / 0.5A max. for 48VDC models

Max. Capacitive Load

Unlimited